SQ-323: Electric Calibration Line Quantum with 3 Sensors

$305.00

Apogee line quantum sensors measure a spatial average of  PAR (Photosynthetically Active Radiation). The SQ-323 has a sensor bar with 3 sensors and is self-powered with a 0 to 800 mV output. The sensor is calibrated for use with electric lights. The sensor housing design features an integrated bubble level and is fully potted making the sensor weatherproof. Typical applications include PPFD (Photosynthetic Photon Flux Density) measurement over plant canopies in outdoor environments, greenhouses, and growth chambers, and reflected or under-canopy (transmitted) PPFD measurements in the same environments. Quantum sensors are also used to measure PAR/PPFD in aquatic environments, including salt water aquariums where corals are grown.

Full Description

Apogee line quantum sensors measure a spatial average of  PAR (Photosynthetically Active Radiation). The SQ-323 has a sensor bar with 3 sensors and is self-powered with a 0 to 800 mV output. The sensor is calibrated for use with electric lights. The sensor housing design features an integrated bubble level and is fully potted making the sensor weatherproof. Typical applications include PPFD (Photosynthetic Photon Flux Density) measurement over plant canopies in outdoor environments, greenhouses, and growth chambers, and reflected or under-canopy (transmitted) PPFD measurements in the same environments. Quantum sensors are also used to measure PAR/PPFD in aquatic environments, including salt water aquariums where corals are grown.

PAR Measurements Characterize Tree Coverages
Using line quantum meter to study the percent of PAR (under canopy/open sky) and its relation to survival and initial growth of native forest species.
Controlling Flowering of Orchids in Greenhouse
Line quantum sensor used to measure PPFD and daily light integral, while experimenting with temperature to control flowering.
Availability: In stock
Current Stock:
Power Supply Self-powered Sensitivity 0.2 mV per µmol m<sup>-2</sup> s<sup>-1</sup> Calibration Factor 5.0 µmol m<sup>-2</sup> s<sup>-1</sup> per mV (reciprocal of sensitivity) Calibration Uncertainty ± 5% Calibrated Output Range 0 to 800 mV Measurement Repeatability Less than 0.5% Non-stability (Long-term Drift) Less than 2 % per year Non-linearity Less than 1 % (up to 4000 µmol m<sup>-2</sup> s<sup>-1</sup>; maximum PPF measurement is 2500 µmol m<sup>-2</sup> s<sup>-1</sup>) Response Time Less than 1 ms Field of View 180° Spectral Range 410 nm to 655 nm Spectral Selectivity Less than 10 % from 469 to 653 nm Directional (Cosine) Response ± 5 % at 75° zenith angle Temperature Response 0.06 ± 0.06 % per C Operating Environment -40 to 70 C, 0 to 100 % relative humidity, can be submerged in water up to depths of 30 m Dimensions 500 mm length, 15 mm width, 15 mm height Mass 275 g (with 5 m of lead wire) Cable 5 m of shielded, twisted-pair wire. Santoprene rubber jacket (high water resistance, high UV stability, flexibility in cold conditions). Pigtail lead wires Warranty 4 years against defects in materials and workmanship
Width: 36.00
Height: 8.00
Depth: 8.00
SKU: SQ-323