SO-110: Soil Response Thermistor Reference Oxygen Sensor

$375.00

The SO-110 has a standard response time of 60 seconds, is designed for use in soil applications, and has high-quality cable terminating in pre-tinned pigtail leads for easy connection to dataloggers and controllers. It comes with a thermistor temperature sensor to correct for temperature changes and a restive heater to raise the temperature of the membrane approximately two degrees above ambient temperature to keep condensation from occurring on the Teflon membrane and blocking the diffusion path of the sensor. Typical applications include measurement of O2 in laboratory experiments, monitoring gaseous O2 in indoor environments for climate control, monitoring of O2 levels in compost piles and mine sailings, monitoring redox potential in soils, and determination of respiration rates through measurement of O2 consumption in sealed chambers or measurement of O2 gradients in soil/porous media.

 

FOR MORE PRODUCT INFORMATION, CHECK OUT THESE LINKS

• Product Manual

• Specification Sheet

• Technical Drawing

 

MORE INFORMATION ON APOGEE OXYGEN SENSORS >> click here

Full Description
Where to Buy

The SO-110 has a standard response time of 60 seconds, is designed for use in soil applications, and has high-quality cable terminating in pre-tinned pigtail leads for easy connection to dataloggers and controllers. It comes with a thermistor temperature sensor to correct for temperature changes and a restive heater to raise the temperature of the membrane approximately two degrees above ambient temperature to keep condensation from occurring on the Teflon membrane and blocking the diffusion path of the sensor. Typical applications include measurement of O2 in laboratory experiments, monitoring gaseous O2 in indoor environments for climate control, monitoring of O2 levels in compost piles and mine sailings, monitoring redox potential in soils, and determination of respiration rates through measurement of O2 consumption in sealed chambers or measurement of O2 gradients in soil/porous media.

 

FOR MORE PRODUCT INFORMATION, CHECK OUT THESE LINKS

• Product Manual

• Specification Sheet

• Technical Drawing

 

MORE INFORMATION ON APOGEE OXYGEN SENSORS >> click here

Current Stock:
Measurement Range 0 to 100 % O₂ Sensitivity (at sea level, 101.3 kPa) 52-58 mV in 21 % O₂, 2.6 mV per % O₂, 26 µV per 0.01 % O₂ Output at 0 % O2 5 % of output at 20.95 % O₂ or 2.5 ± 1 mV Response Time (time required to read 90 % of saturated response) 60 s Measurement Repeatability Less than 0.1 % of mV output at 20.95 % O₂ Non-linearity Less than 1 % Signal Decrease per Year 1 mV per year Oxygen Consumption Rate 0.1 µmol O₂ per day at 20.95 % O₂ and 23 C Operating Environment -20 to 60 C, 0 to 100 % relative humidity (non-condensing); 60 to 140 kPa Input Voltage Requirement 12 V DC continuous (for heater), 2.5 V DC excitation (for thermistor) Heater Current Drain 6.2 mA (74 mW power requirement when powered with 12 V DC source) Thermistor Current Drain 0.1 mA DC at 70 C (maximum, assuming input excitation of 2.5 V DC) Dimensions 32 mm diameter, 68 mm length Mass 175 g (with 5 m of lead wire) Cable 5 m of six conductor, shielded, twisted-pair wire Warranty 4 years against defects in materials and workmanship Manufactured Made in the USA