Menu
Apogee Instruments, Inc.
  • Home
  • Products
    • Pyranometers
    • Quantum (PAR) Sensors / Meters
    • Daily Light Integral Measurement
    • Infrared Radiometers
    • Aspirated Radiation Shield
    • Spectroradiometers
    • Net Radiometer
    • Pyrgeometers
    • Humidity Probes
    • Temperature Sensors
    • Leaf and Bud Temperature Sensor
    • Oxygen Sensors
    • UV Sensors
    • Chlorophyll Concentration
    • Barometric Pressure
    • PAR Meters for Aquariums
    • microCache Bluetooth Micro Logger
    • Red - Far-red and PAR-FAR Sensors
    • Photometric Sensor
    • Solar Energy PV Monitoring
    • Accessories
    • Calibration Services
    • Replacement Cables
  • ABOUT US
    • Contact Us
    • International Distributors
      • Apogee Instruments Distributors - Brazil
      • Apogee Distributor - Campbell Scientific Southeast Asia
    • Careers
    • Apogee News
    • Company History
    • Event Calendar
    • Staff Listing
    • Apogee Cares
    • Our Founder - Dr. Bruce Bugbee
    • Distributor Application
  • Integrators
  • Support
  • Sign In / Register
  • Search
  • International Distributors
  • My Cart (0)
    Your cart is empty

Extended Range PFD Sensor Support

Extended range PFD sensor support

Introduction
Specifications
Videos
Product Manuals
Spec Sheets
Technical Drawings
FAQs
Software & Datalogger Programs
Recalibration & Repair
Applications and Uses

 

Extended Range PFD Sensor Introduction

Radiation that drives photosynthesis is called photosynthetically active radiation (PAR) and is typically defined as total radiation across a range of 400 to 700 nm. PAR is almost universally quantified as photosynthetic photon flux density (PPFD) in units of micromoles per square meter per second (µmol m-2 s-1, equal to microEinsteins per square meter per second) summed from 400 to 700 nm (total number of photons from 400 to 700 nm). However, ultraviolet and far red photons outside the defined PAR range of 400-700 nm can also contribute to photosynthesis and influence plant responses (e.g., flowering).

Sensors that measure PPFD are often called quantum sensors due to the quantized nature of radiation. A quantum refers to the minimum quantity of radiation, one photon, involved in physical interactions (e.g., absorption by photosynthetic pigments). In other words, one photon is a single quantum of radiation. Sensors that function like traditional quantum sensors, but measure a wider range of wavelengths can be thought of as an ‘extended range’ quantum sensor.

Typical applications of traditional quantum sensors include incoming PPFD measurement over plant canopies in outdoor environments or in greenhouses and growth chambers, and reflected or under-canopy (transmitted) PPFD measurement in the same environments. The Extended Range Quantum Sensor uses a detector that is sensitive to radiation up to about 1100 nm, well beyond the range of wavelengths that influence photosynthesis and plant responses. This means this particular sensor should only be used for photon flux density measurements under LEDs.

 

Extended Range PFD Sensor Specifications
Apogee Instruments Extended Range PFD Sensor Specifications
  SQ-620-SS SQ-622-SS SQ-624-SS SQ-625-SS SQ-626 SQ-627-SS
Power Supply Self-powered 5 to 24 V DC 12 to 24 V DC 5.5 to 24 V DC 5 V USB power source 5.5 to 24 V DC
Current Draw - at 12 V is 57 µA Maximum of 20 mA at 12 V is 57 µA 61 mA when logging 1.4 mA (quiescent), 1.8 mA (active)
Sensitivity 0.05 mV per µmol m-2 s-1 0.625 mV per µmol m-2 s-1 0.004 mA per µmol m-2 s-1 1.25 mV per µmol m-2 s-1 - -
Output Type 0 to 200 mV 0 to 2.5 V 4 to 20 mA 0 to 5 V USB SDI-12
Resolution - - - - 0.1 µmol m-2 s-1 -
Calibration Factor 20 µmol m-2 s-1 per mV 1.6 µmol m-2 s-1 per mV 250 µmol m-2 s-1 per mA 0.8 µmol m-2 s-1 per mV Custom for each sensor and stored in the firmware Custom for each sensor and stored in the firmware
Calibration Uncertainty ± 5 % ± 5 % ± 5 % ± 5 % ± 5 % ± 5 %
Measurement Range 0 to 4000 µmol m-2 s-1 0 to 4000 µmol m-2 s-1 0 to 4000 µmol m-2 s-1 0 to 4000 µmol m-2 s-1 0 to 4000 µmol m-2 s-1 0 to 4000 µmol m-2 s-1
Measurement Repeatability Less than 0.5 % Less than 0.5 % Less than 0.5 % Less than 0.5 % Less than 0.5 % Less than 0.5 %
Long-term Drift per Year Less than 2 % per year Less than 2 % per year Less than 2 % per year Less than 2 % per year Less than 2 % per year Less than 2 % per year
Non-linearity Less than 1 % (up to 4000 µmol m-2 s-1) Less than 1 % (up to 4000 µmol m-2 s-1) Less than 1 % (up to 4000 µmol m-2 s-1) Less than 1 % (up to 4000 µmol m-2 s-1) Less than 1 % (up to 4000 µmol m-2 s-1) Less than 1 % (up to 4000 µmol m-2 s-1)
Response Time Less than 1 ms Less than 1 ms Less than 1 ms Less than 1 ms Software updates every second Less than 0.6 s
Field of View 180° 180° 180° 180° 180° 180°
Spectral Range 340 to 1040 nm ± 5 nm (wavelengths where response is greater than 50 % of maximum) 340 to 1040 nm ± 5 nm (wavelengths where response is greater than 50 % of maximum) 340 to 1040 nm ± 5 nm (wavelengths where response is greater than 50 % of maximum) 340 to 1040 nm ± 5 nm (wavelengths where response is greater than 50 % of maximum) 340 to 1040 nm ± 5 nm (wavelengths where response is greater than 50 % of maximum) 340 to 1040 nm ± 5 nm (wavelengths where response is greater than 50 % of maximum)
Directional (Cosine) Response ± 2 % at 45°; ± 5 % at 75° zenith angle ± 2 % at 45°; ± 5 % at 75° zenith angle ± 2 % at 45°; ± 5 % at 75° zenith angle ± 2 % at 45°; ± 5 % at 75° zenith angle ± 2 % at 45°; ± 5 % at 75° zenith angle ± 2 % at 45°; ± 5 % at 75° zenith angle
Azimuth Error Less than 0.5 % Less than 0.5 % Less than 0.5 % Less than 0.5 % Less than 0.5 % Less than 0.5 %
Tilt Error Less than 0.5 % Less than 0.5 % Less than 0.5 % Less than 0.5 % Less than 0.5 % Less than 0.5 %
Temperature Response -0.11 ± 0.04 % per C -0.11 ± 0.04 % per C -0.11 ± 0.04 % per C -0.11 ± 0.04 % per C -0.11 ± 0.04 % per C -0.11 ± 0.04 % per C
Uncertainty in Daily Total Less than 5 % Less than 5 % Less than 5 % Less than 5 % Less than 5 % Less than 5 %
Housing Anodized aluminum body with acrylic diffuser Anodized aluminum body with acrylic diffuser Anodized aluminum body with acrylic diffuser Anodized aluminum body with acrylic diffuser Anodized aluminum body with acrylic diffuser Anodized aluminum body with acrylic diffuser
IP Rating IP68 IP68 IP68 IP68 IP68 IP68
Operating Environment -40 to 70 C; 0 to 100 % relative humidity; can be submerged in water up to depths of 30 m -40 to 70 C; 0 to 100 % relative humidity; can be submerged in water up to depths of 30 m -40 to 70 C; 0 to 100 % relative humidity; can be submerged in water up to depths of 30 m -40 to 70 C; 0 to 100 % relative humidity; can be submerged in water up to depths of 30 m -40 to 70 C; 0 to 100 % relative humidity; can be submerged in water up to depths of 30 m -40 to 70 C; 0 to 100 % relative humidity; can be submerged in water up to depths of 30 m
Dimensions 30.5 mm diameter, 37 mm height 30.5 mm diameter, 37 mm height 30.5 mm diameter, 37 mm height 30.5 mm diameter, 37 mm height 30.5 mm diameter, 37 mm height 30.5 mm diameter, 37 mm height
Mass (with 5 m of cable) 140 g 140 g 140 g 140 g 140 g 140 g
Warranty 4 years against defects in materials and workmanship 4 years against defects in materials and workmanship 4 years against defects in materials and workmanship 4 years against defects in materials and workmanship 4 years against defects in materials and workmanship 4 years against defects in materials and workmanship

 

Extended Range PFD Sensor Videos
Apogee Instruments Extended Range PFD Sensor Videos

Predicting Stem Elongation and Leaf Expansion: Percent far-red is a better predictor than PPE

If you can't access the video via Youtube, click here.

Far-red: The Forgotten Photons

If you can't access the video via Youtube, click here.

Turning Photons Into Food

If you can't access the video via Youtube, click here.

Toward an Optimal Spectral Quality for Plant Growth and Development

If you can't access the video via Youtube, click here.

PAR, PPF, PPFD, and PFD Explained

Photobiology Simplified with Dr Bruce Bugbee

If you can't access the video via Youtube, click here.

 

Extended Range PFD Product Manuals
Product Manuals Icon
SQ-620-SS
SQ-622-SS
SQ-624-SS
SQ-625-SS
SQ-626
SQ-627-SS
MQ-620

 

Extended Range PFD Sensor Specification Sheets
Specification Sheets Icon

Extended Range PFD Spec Sheet (SQ-620 Series) >

 

Extended Range PFD Sensor Technical Drawings
Technical Drawings Icon
SQ-620-SS
SQ-622-SS
SQ-624-SS
SQ-625-SS
SQ-626
SQ-627-SS
MQ-620

 

  FAQs

 What are the new in-line cable connectors?

 

Didn't find your answer?

  1. Home
  2. / Quantum (PAR) Sensors / Meters
  3. / Extended Range PFD Sensors
  4. / Extended Range PFD Sensor Support

Shop by brand

  • Apogee
  • Campbell Scientifice

Shop by price

  • $0.00 - $147.00
  • $147.00 - $270.00
  • $270.00 - $393.00
  • $393.00 - $516.00
  • $516.00 - $639.00
PQ-620 Package: microCache and Extended Range PFD sensor with 30 cm cable
Quick View

PQ-620 Package: microCache and Extended Range PFD sensor with 30 cm cable

$619.00
PQ-622 Package: microCache and Extended Range PFD Sensor with 2 meter cable
Quick View

PQ-622 Package: microCache and Extended Range PFD Sensor with 2 meter cable

$639.00
MQ-620: 340-1040 nm Extended Range PFD Meter
Quick View

MQ-620: 340-1040 nm Extended Range PFD Meter

$568.00
SQ-620-SS 340-1040 nm Extended Range PFD Sensor
Quick View

SQ-620-SS 340-1040 nm Extended Range PFD Sensor

$415.00
SQ-622-SS 340-1040 nm 0-2.5 V output Extended Range PFD Sensor
Quick View

SQ-622-SS 340-1040 nm 0-2.5 V output Extended Range PFD Sensor

$460.00
SQ-624-SS 340-1040 nm 4-20 mA output Extended Range PFD Sensor
Quick View

SQ-624-SS 340-1040 nm 4-20 mA output Extended Range PFD Sensor

$515.00
SQ-625-SS 340-1040 nm 0-5 V output Extended Range PFD Sensor
Quick View

SQ-625-SS 340-1040 nm 0-5 V output Extended Range PFD Sensor

$460.00
SQ-626: 340-1040 nm USB output Extended Range PFD Sensor
Quick View

SQ-626: 340-1040 nm USB output Extended Range PFD Sensor

$465.00
SQ-627-SS 340-1040 nm SDI-12 Extended Range PFD Sensor
Quick View

SQ-627-SS 340-1040 nm SDI-12 Extended Range PFD Sensor

$515.00
AA-100: Protective Carrying Case
Quick View

AA-100: Protective Carrying Case

$24.00
AL-100: Solar Sensor Leveling Plate
Quick View

AL-100: Solar Sensor Leveling Plate

$44.00
AL-120 Solar Mounting Bracket with Leveling Plate
Quick View

AL-120 Solar Mounting Bracket with Leveling Plate

$64.00
AM-310: Sensor Wand
Quick View

AM-310: Sensor Wand

$62.00

Compare Products

Subscribe to Our newsletter

About Apogee Instruments, Inc.

Address:
721 West 1800 North
Logan, UT 84321
United States of America

Hours: Monday-Friday 8 AM- 5 PM MST

Main Line / Order Status: (435) 792-4700
or sales@apogeeinstruments.com

Technical Sales and Support: (435) 245-8012
or techsupport@apogeeinstruments.com

Purchase

  • Products
  • Product Catalog
  • Case Studies
  • International Distributors
  • Integrators

Support

  • Technical Support
  • Sales Support
  • Product Manuals
  • Recalibration & Repair
  • Downloads
  • Sign In / Register
  • Sitemap

Company

  • Contact Us
  • Company History
  • Apogee News
  • Event Calendar
  • Careers
© Apogee Instruments, Inc.

Search in Apogee Instruments, Inc.

Cart Checkout
  • products
    • Pyranometers
    • Quantum (PAR) Sensors / Meters
    • Daily Light Integral Measurement
    • Infrared Radiometers
    • Aspirated Radiation Shield
    • Spectroradiometers
    • Net Radiometer
    • Pyrgeometers
    • Humidity Probes
    • Temperature Sensors
    • Leaf and Bud Temperature Sensor
    • Oxygen Sensors
    • UV Sensors
    • Chlorophyll Concentration
    • Barometric Pressure
    • PAR Meters for Aquariums
    • microCache Bluetooth Micro Logger
    • Red - Far-red and PAR-FAR Sensors
    • Photometric Sensor
    • Solar Energy PV Monitoring
    • Accessories
    • Calibration Services
    • Replacement Cables
  • About Us
    • Contact Us
    • International Distributors
      • Apogee Instruments Distributors - Brazil
      • Apogee Distributor - Campbell Scientific Southeast Asia
    • Careers
    • Apogee News
    • Company History
    • Event Calendar
    • Staff Listing
    • Apogee Cares
    • Our Founder - Dr. Bruce Bugbee
    • Distributor Application
  • Integrators
  • Blog
  • Support
  • Account
    • Sign In / Register
    • Returns
More Info